Save everyday and everything with us! Join Free or Sign in

{"id":9644153864450,"title":"APC NetShelter Metered Switched Rack PDU AP8659","handle":"apc-netshelter-metered-switched-rack-pdu-ap8659","description":"\u003cp style=\"margin:1em 0\"\u003eThe APC NetShelter AP8659 is a 0U metered-by-outlet with switching rack power distribution unit engineered for high-density IT environments requiring granular power monitoring and remote control. Operating on a 16A, 230V single-phase feed via an IEC C20 inlet, it delivers real-time per-outlet current, power, and energy metering to ±3% accuracy across 24 locking outlets (21 IEC C13 and 3 IEC C19).\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eEquipped with individual outlet power cycling, sequencing delays, and user-defined alarm thresholds, the AP8659 enables remote rebooting of unresponsive hardware and prevents circuit overloads. Integrated network management supports Web, HTTPS, SNMP, Telnet, and SSH protocols with EcoStruxure IT integration, complemented by an onboard digital display and an environmental sensor port for optional temperature and humidity monitoring.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eConstructed in a space-saving 0U vertical form factor measuring 1,829 mm in height, this PDU mounts toollessly in standard rack enclosures without consuming critical horizontal rack units. Built to operate reliably in operating temperatures ranging from -5 to 60 °C, it provides dependable power distribution and infrastructure visibility for mission-critical enterprise and data center applications.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eAPC Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eAP8659\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMetered-by-Outlet with Switching Rack PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e0U (Vertical Mount)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e200 V, 208 V, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eAcceptable Input Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e100–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e16 A at 230 V (20 A at 208 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eInput Connection\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eIEC 60320 C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e21 x IEC 60320 C13, 3 x IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e230 V (also 100 V, 200 V, 208 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMetering Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003ePer-outlet and device-level (amps, volts, kW, kWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSwitching Capabilities\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eIndividual outlet on\/off and power cycling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eWeb, HTTPS, SNMP, Telnet, SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e182.9 x 5.6 x 5.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e6.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e8.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e-5 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e5 to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","published_at":"2026-09-21T21:28:00+08:00","created_at":"2026-09-21T21:27:53+08:00","vendor":"APC Schneider Electric","type":"","tags":["0U rack PDU","16A 230V PDU","APC AP8659","APC NetShelter PDU","Created by Product Upload","data center PDU","metered by outlet PDU","server rack power strip","switched rack PDU"],"price":225400,"price_min":225400,"price_max":225400,"available":true,"price_varies":false,"compare_at_price":270480,"compare_at_price_min":270480,"compare_at_price_max":270480,"compare_at_price_varies":false,"variants":[{"id":48536856133890,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AP8659","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"APC NetShelter Metered Switched Rack PDU AP8659","public_title":null,"options":["Default Title"],"price":225400,"weight":8360,"compare_at_price":270480,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/lioncityco.com\/cdn\/shop\/files\/files_9c9eb646-916a-4d62-b3df-b159831fa20d.jpg?v=1789997278"],"featured_image":"\/\/lioncityco.com\/cdn\/shop\/files\/files_9c9eb646-916a-4d62-b3df-b159831fa20d.jpg?v=1789997278","options":["Title"],"media":[{"alt":"APC NetShelter Metered Switched Rack PDU AP8659","id":40636284141826,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/lioncityco.com\/cdn\/shop\/files\/files_9c9eb646-916a-4d62-b3df-b159831fa20d.jpg?v=1789997278"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/lioncityco.com\/cdn\/shop\/files\/files_9c9eb646-916a-4d62-b3df-b159831fa20d.jpg?v=1789997278","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"margin:1em 0\"\u003eThe APC NetShelter AP8659 is a 0U metered-by-outlet with switching rack power distribution unit engineered for high-density IT environments requiring granular power monitoring and remote control. Operating on a 16A, 230V single-phase feed via an IEC C20 inlet, it delivers real-time per-outlet current, power, and energy metering to ±3% accuracy across 24 locking outlets (21 IEC C13 and 3 IEC C19).\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eEquipped with individual outlet power cycling, sequencing delays, and user-defined alarm thresholds, the AP8659 enables remote rebooting of unresponsive hardware and prevents circuit overloads. Integrated network management supports Web, HTTPS, SNMP, Telnet, and SSH protocols with EcoStruxure IT integration, complemented by an onboard digital display and an environmental sensor port for optional temperature and humidity monitoring.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eConstructed in a space-saving 0U vertical form factor measuring 1,829 mm in height, this PDU mounts toollessly in standard rack enclosures without consuming critical horizontal rack units. Built to operate reliably in operating temperatures ranging from -5 to 60 °C, it provides dependable power distribution and infrastructure visibility for mission-critical enterprise and data center applications.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eAPC Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eAP8659\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMetered-by-Outlet with Switching Rack PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e0U (Vertical Mount)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e200 V, 208 V, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eAcceptable Input Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e100–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e16 A at 230 V (20 A at 208 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eInput Connection\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eIEC 60320 C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e21 x IEC 60320 C13, 3 x IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e230 V (also 100 V, 200 V, 208 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMetering Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003ePer-outlet and device-level (amps, volts, kW, kWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSwitching Capabilities\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eIndividual outlet on\/off and power cycling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eWeb, HTTPS, SNMP, Telnet, SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e182.9 x 5.6 x 5.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e6.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e8.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e-5 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e5 to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e"}

APC NetShelter Metered Switched Rack PDU AP8659

Disclaimer: We strive to present product information as accurately as possible by sourcing directly from the manufacturer/agent. Specifications and prices are subject to change without prior notice. Consumers are highly recommended to verify the latest specs on the manufacturer’s site. Pictures are for illustration purposes only. Order placement does not guarantee immediate stock availability or price locking. Prices for Samsung SSDs and NVIDIA products are subject to the prevailing market price upon stock arrival and cannot be guaranteed at the time of order placement. Full payment may be required upfront for such orders. If the final supplier price increases upon stock arrival, customers will be informed of the revised price. Should the customer choose not to proceed with the revised price, the order will be cancelled and a full refund will be issued. In the event we are unable to fulfill your order due to stock depletion, manufacturer price increases, supplier pricing revisions, or listing errors, we will contact you with alternatives or process a cancellation. All refunds are issued in accordance with our prevailing Refund Policy. 

APC NetShelter Metered Switched Rack PDU AP8659

$2,254.00 $2,704.80
Maximum quantity available reached.
Best Price Gurantee

Note: To avoid disappointment, please verify with us for stock availability before purchasing.

Electronic appliances Singapore

Pay with Atome to save an extra $50!
How to Claim →
Product Description

The APC NetShelter AP8659 is a 0U metered-by-outlet with switching rack power distribution unit engineered for high-density IT environments requiring granular power monitoring and remote control. Operating on a 16A, 230V single-phase feed via an IEC C20 inlet, it delivers real-time per-outlet current, power, and energy metering to ±3% accuracy across 24 locking outlets (21 IEC C13 and 3 IEC C19).

Equipped with individual outlet power cycling, sequencing delays, and user-defined alarm thresholds, the AP8659 enables remote rebooting of unresponsive hardware and prevents circuit overloads. Integrated network management supports Web, HTTPS, SNMP, Telnet, and SSH protocols with EcoStruxure IT integration, complemented by an onboard digital display and an environmental sensor port for optional temperature and humidity monitoring.

Constructed in a space-saving 0U vertical form factor measuring 1,829 mm in height, this PDU mounts toollessly in standard rack enclosures without consuming critical horizontal rack units. Built to operate reliably in operating temperatures ranging from -5 to 60 °C, it provides dependable power distribution and infrastructure visibility for mission-critical enterprise and data center applications.

Brand APC Schneider Electric
Model Number AP8659
Product Type Metered-by-Outlet with Switching Rack PDU
Form Factor 0U (Vertical Mount)
Phase Single Phase
Nominal Input Voltage 200 V, 208 V, 230 V
Acceptable Input Voltage 100–240 VAC
Input Frequency 50/60 Hz
Maximum Input Current 16 A at 230 V (20 A at 208 V)
Input Connection IEC 60320 C20
Output Receptacles 21 x IEC 60320 C13, 3 x IEC 60320 C19
Output Voltage 230 V (also 100 V, 200 V, 208 V)
Metering Type Per-outlet and device-level (amps, volts, kW, kWh)
Metering Accuracy ±3%
Switching Capabilities Individual outlet on/off and power cycling
Management Protocols Web, HTTPS, SNMP, Telnet, SSH
Dimensions (H x W x D) 182.9 x 5.6 x 5.1 cm
Product Weight 6.09 kg
Shipping Weight 8.36 kg
Operating Temperature -5 to 60 °C
Operating Relative Humidity 5 to 95%
Operating Elevation 0 to 3,000 m
Color Black