Save everyday and everything with us! Join Free or Sign in

{"id":9644619038978,"title":"APC NetShelter 9000 Switched Rack PDU 0U 32A 230V APDU9953","handle":"apc-netshelter-9000-switched-rack-pdu-0u-32a-230v-apdu9953","description":"\u003cp style=\"margin:1em 0\"\u003eThe APC NetShelter 9000 Switched Rack PDU APDU9953 delivers reliable, intelligent power distribution for high-density server rack environments. Engineered with a 32A single-phase input and a 7,400 VA capacity, it features a 0U vertical form factor powered by an attached 3 m IEC 60309 cord. Equipped with twenty-one IEC C13 and three IEC C19 hybrid locking outlets, it ensures secure connectivity and ample support for mission-critical enterprise hardware.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eFeaturing remote individual outlet switching and power sequencing, this switched PDU allows administrators to reboot hung devices, manage power-up delays, and prevent circuit overloads without physical site visits. Built-in network metering tracks current, voltage, and total power in real time, with configurable alarm thresholds to safeguard connected equipment against unexpected branch circuit overdraws.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eThe upgraded NetShelter 9000 platform integrates Gigabit Ethernet via Schneider Electric's NMC3 architecture, offering full compatibility with EcoStruxure IT, SNMP, SSH, and web interfaces. An intuitive local LCD screen provides direct status monitoring, while Link ports enable Network Port Sharing across multiple units. Built-in universal sensor ports support environmental monitoring to optimize airflow and thermal management in dense 42U racks.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eAPDU9953\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSwitched Rack Power Distribution Unit (PDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e0U (Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e200 V \/ 208 V \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eInput Connection\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eIEC 60309 32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCord Length\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e7400 VA (7360 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eTotal Outlets\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e21 x IEC 60320 C13, 3 x IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eIndividual remote outlet control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMetering\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCurrent, Power, and Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eGigabit Ethernet (10\/100\/1000BASE-T), NMC3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProtocols \u0026amp; Management\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eWeb, SNMP, SSH, EcoStruxure IT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e182.9 x 5.6 x 4.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e7.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e9.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","published_at":"2026-09-22T03:23:39+08:00","created_at":"2026-09-22T03:23:37+08:00","vendor":"APC by Schneider Electric","type":"","tags":["0U PDU","230V PDU","32A PDU","APC","APDU9953","Created by Product Upload","NetShelter 9000","Power Distribution Unit","Server Rack PDU","Switched Rack PDU"],"price":159132,"price_min":159132,"price_max":159132,"available":true,"price_varies":false,"compare_at_price":190958,"compare_at_price_min":190958,"compare_at_price_max":190958,"compare_at_price_varies":false,"variants":[{"id":48537713344770,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"APDU9953","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"APC NetShelter 9000 Switched Rack PDU 0U 32A 230V APDU9953","public_title":null,"options":["Default Title"],"price":159132,"weight":9950,"compare_at_price":190958,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/lioncityco.com\/cdn\/shop\/files\/files_8a90682b-b80a-4d59-8584-913873bbcde5.jpg?v=1790018619"],"featured_image":"\/\/lioncityco.com\/cdn\/shop\/files\/files_8a90682b-b80a-4d59-8584-913873bbcde5.jpg?v=1790018619","options":["Title"],"media":[{"alt":"APC NetShelter 9000 Switched Rack PDU 0U 32A 230V APDU9953","id":40639473418498,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/lioncityco.com\/cdn\/shop\/files\/files_8a90682b-b80a-4d59-8584-913873bbcde5.jpg?v=1790018619"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/lioncityco.com\/cdn\/shop\/files\/files_8a90682b-b80a-4d59-8584-913873bbcde5.jpg?v=1790018619","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"margin:1em 0\"\u003eThe APC NetShelter 9000 Switched Rack PDU APDU9953 delivers reliable, intelligent power distribution for high-density server rack environments. Engineered with a 32A single-phase input and a 7,400 VA capacity, it features a 0U vertical form factor powered by an attached 3 m IEC 60309 cord. Equipped with twenty-one IEC C13 and three IEC C19 hybrid locking outlets, it ensures secure connectivity and ample support for mission-critical enterprise hardware.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eFeaturing remote individual outlet switching and power sequencing, this switched PDU allows administrators to reboot hung devices, manage power-up delays, and prevent circuit overloads without physical site visits. Built-in network metering tracks current, voltage, and total power in real time, with configurable alarm thresholds to safeguard connected equipment against unexpected branch circuit overdraws.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eThe upgraded NetShelter 9000 platform integrates Gigabit Ethernet via Schneider Electric's NMC3 architecture, offering full compatibility with EcoStruxure IT, SNMP, SSH, and web interfaces. An intuitive local LCD screen provides direct status monitoring, while Link ports enable Network Port Sharing across multiple units. Built-in universal sensor ports support environmental monitoring to optimize airflow and thermal management in dense 42U racks.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eAPDU9953\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSwitched Rack Power Distribution Unit (PDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e0U (Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e200 V \/ 208 V \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eInput Connection\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eIEC 60309 32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCord Length\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e7400 VA (7360 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eTotal Outlets\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e21 x IEC 60320 C13, 3 x IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eIndividual remote outlet control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMetering\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCurrent, Power, and Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eGigabit Ethernet (10\/100\/1000BASE-T), NMC3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProtocols \u0026amp; Management\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eWeb, SNMP, SSH, EcoStruxure IT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e182.9 x 5.6 x 4.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e7.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e9.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e"}

APC NetShelter 9000 Switched Rack PDU 0U 32A 230V APDU9953

Disclaimer: We strive to present product information as accurately as possible by sourcing directly from the manufacturer/agent. Specifications and prices are subject to change without prior notice. Consumers are highly recommended to verify the latest specs on the manufacturer’s site. Pictures are for illustration purposes only. Order placement does not guarantee immediate stock availability or price locking. Prices for Samsung SSDs and NVIDIA products are subject to the prevailing market price upon stock arrival and cannot be guaranteed at the time of order placement. Full payment may be required upfront for such orders. If the final supplier price increases upon stock arrival, customers will be informed of the revised price. Should the customer choose not to proceed with the revised price, the order will be cancelled and a full refund will be issued. In the event we are unable to fulfill your order due to stock depletion, manufacturer price increases, supplier pricing revisions, or listing errors, we will contact you with alternatives or process a cancellation. All refunds are issued in accordance with our prevailing Refund Policy. 

APC NetShelter 9000 Switched Rack PDU 0U 32A 230V APDU9953

$1,591.32 $1,909.58
Maximum quantity available reached.
Best Price Gurantee

Note: To avoid disappointment, please verify with us for stock availability before purchasing.

Electronic appliances Singapore

Pay with Atome to save an extra $15!
How to Claim →
Product Description

The APC NetShelter 9000 Switched Rack PDU APDU9953 delivers reliable, intelligent power distribution for high-density server rack environments. Engineered with a 32A single-phase input and a 7,400 VA capacity, it features a 0U vertical form factor powered by an attached 3 m IEC 60309 cord. Equipped with twenty-one IEC C13 and three IEC C19 hybrid locking outlets, it ensures secure connectivity and ample support for mission-critical enterprise hardware.

Featuring remote individual outlet switching and power sequencing, this switched PDU allows administrators to reboot hung devices, manage power-up delays, and prevent circuit overloads without physical site visits. Built-in network metering tracks current, voltage, and total power in real time, with configurable alarm thresholds to safeguard connected equipment against unexpected branch circuit overdraws.

The upgraded NetShelter 9000 platform integrates Gigabit Ethernet via Schneider Electric's NMC3 architecture, offering full compatibility with EcoStruxure IT, SNMP, SSH, and web interfaces. An intuitive local LCD screen provides direct status monitoring, while Link ports enable Network Port Sharing across multiple units. Built-in universal sensor ports support environmental monitoring to optimize airflow and thermal management in dense 42U racks.

Brand APC by Schneider Electric
Manufacturer Schneider Electric
Model Number APDU9953
Product Type Switched Rack Power Distribution Unit (PDU)
Form Factor 0U (Vertical)
Nominal Input Voltage 200 V / 208 V / 230 V
Input Connection IEC 60309 32A
Cord Length 3.0 m
Maximum Input Current 32 A
Maximum Load Capacity 7400 VA (7360 W)
Input Frequency 50/60 Hz
Phase Single Phase
Total Outlets 24
Output Receptacles 21 x IEC 60320 C13, 3 x IEC 60320 C19
Output Voltage 230 V
Outlet Switching Individual remote outlet control
Metering Current, Power, and Voltage
Network Interface Gigabit Ethernet (10/100/1000BASE-T), NMC3
Protocols & Management Web, SNMP, SSH, EcoStruxure IT
Dimensions (H x W x D) 182.9 x 5.6 x 4.6 cm
Net Weight 7.34 kg
Shipping Weight 9.95 kg
Operating Temperature -5 to 45 °C
Color Black
Sku: APDU9953

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)